They control and automate electric submersible pump (ESP) systems and horizontal pump systems (HPS) to improve run life and handle changing production conditions.
Besides varying pump speed to match load, advanced VSDs actively monitor system parameters (vibration, current, load swings), enabling detection of anomalies early (before failure), reducing mechanical stress, and optimizing power usage.
A single downhole sensor is typically installed to track downhole temperature, pressure, motor current/voltage, vibration, and sometimes flow rate. Feeding this data into external monitoring helps identify issues early.
Power line harmonics are distortions in electrical waveforms caused by non-linear loads which can lead to reduced equipment efficiency, penalties from utility companies, and potential damage to motors or controls. Valiant can analyze and mitigate them.
Yes — our solutions are generally compatible with most variable speed drives on the market. Proper assessment ensures the existing equipment can support the application’s demands without introducing failure points.